Pensioners Power Plant 01 — Intro
May 2026
The EPC C House
In 2025 my parents purchased a bungalow to be their retirement home. The house is 2 bedroom, 60 square metres, was built in 1996 and has an EPC rating C. So my guestimation is a gas bill of £600 per year.
So stage 1 of the journey was actually getting the Air Source Heat Pump (which will be covered in another section, and although I knew that Octopus Agile would happily support the heat pump at the same price as gas (18p/kWh divided by SCOP of 4 = 4.5p/kWh), it would make sense to go all in and proceed with stage 2, which was to power that Heat Pump with Solar.
The house had a very early 90s looking consumer unit that was cracked - yet somehow the seller’s electrician managed to sign off an EICR for that… Anyway we decided that had to go too for a modern metal consumer unit as part of the whole solar project, which added to the cost.
How I approach Solar PV Systems choice
My Youtube history is basically Green Energy, Solar PV, and Cars. After years of following green energy, I generally research and know a product and then ask for that to be quoted. I was lucky enough to organise & oversee a GivEnergy 3-phase Solar PV installation for Church in March 2025 and come August 2025, I was asking for GivEnergy & Sigenergy quotes. Both solar installers who came to quote basically dismissed GivEnergy and said Sigenergy would be in budget. The installers seemed to really rate Sigenergy and I already knew from first hand experience how poor GivEnergy software bugs were. (And now we know that GivEnergy has sadly gone into administration in 2026).
Solar PV Panels
The wonderful south facing roof was going to be maxed out with 7.2kW of Solar PV panels and although Darroch who came to quote, asked me what do you think about a north facing array? - he basically read my mind, but unfortunately the £2k premium for that was too much, so we only went with the South facing array.
Although I mentioned I wanted panels like Trina or REC bi-facial, Darroch recommended AIKO (mono facial), and now that has turned out to be a great choice. It comes top for value and is only a little behind REC. The efficiency is 23% and has a great heat coefficient. I think we are fine without bi-facial since the panels are mounted so close to the roof, there would not be that much light bouncing off the roof to the rear of the panels.
Although the second installer’s quote came back with 16 panels of 450W, Darroch & Scott said that only 14 would fit (we are talking about the same physical dimensions). Therefore to compensate, Scott sourced 510W panels, giving me 7140W array which was close enough to the alternative (and impossible) 16 panel 7200W array. The flexibility from Scott was really great throughout the quoting process, he had to accommodate all my different questions and scenarios! (moving old EV charger, North array, EVDC…)
Now I’ve actually seen the 7.14kW array generate at a peak of 8.3kW in May! (You always get your best production after a bit of cloud cover breaking into full sunshine).
DNO Application
The DNO surprised me with permission for the full 8kW of our Sigenergy 8kW inverter! I thought we would get only 5kW given how many solar installations there are in the neighbourhood, so I felt we were really lucky. I honestly think if we had a 10kW inverter, they would have throttled us down to 5kW export. Anyway we have 7.14 kW of panels, so I don’t have to worry about clipping.
The Gateway
Since this is my parents retirement home, it was prudent to make it ready for future eventualities. There are rarely any power cuts in the town but you never know if you will be running devices that need continuous power. Sidestory: In 2015, my sister lived in a hamlet 5 miles away in old Workers Cottages where the elderly neighbour who was on a respirator, sadly passed away during an overnight powercut. We can solve this nowadays with Anker/EcoFlow batteries, but back then they weren’t so prevalent. So for the ~£800 premium for the Sigenergy Gateway and especially since we were fully replacing & relocating the consumer unit, it made sense to install it.
So when there is a powercut, all non-gateway Solar PV systems stop producing power, even if you have a battery and blazing sunshine. This is to prevent electricity exporting out and electrocuting anyone working on fixing the powercut. The way around this is using a Gateway that isolates you from the grid in “islanding mode” and you can be happily generating power.
I guess in a power cut my parents won’t even know, the heat pump will still be running, the home battery will still charge from solar and we can run some long extension leads to the neighbours to share some juice
The alternative is EPS (Emergency Power Supply), which are separate circuits sitting behind the inverter that supplies some sockets/lights that you designated to be protected. This has a limit of a lower power rating (typically 3kW). This might be fine if you have sockets next to the inverter, but can be a false economy as it might require a second consumer unit, lots of wiring around the house and therefore there could be a lot of labour cost.
Since we also have the Signenergy EVDC bi-directional (see chapter below), I have found that the Vehicle-2-Home (V2H) can also support the house in off-grid mode. And if we are low on home battery power, we could drive the EV to a public charger to juice up, and then bring back home to power the house. That’s our strategy to avoid any petrol/diesel generator.
EV Charging & V2G/V2H
Now I’ve been waiting since 2019 for V2G (Vehicle-to-Grid) to be commercially available, we nearly signed up to the OVO Energy V2G with Nissan Leaf trial. And I’ve seen countless videos of it working in the Netherlands. So I decided the Signenergy EVDC was a toy I had to have. What about the health of the battery? A few extra charges won’t stress the EV battery so much, especially if you keep it in the 20-70% SoC range. I also believe that EVs are likely to fail their MOTs from rust well before the battery loses useful life, so I failed MOT Renault Zoe could sit on the driveway to be a second battery.
So we specified the 12.5kW EVDC charger (£2800) instead of the 25kW, since the inverter is only 8kW the higher 25kW model will be struggling to reach the max rate. We opted for the longer 10m cable too. We don’t really need the 10m but the voltage drop over the extra 5m is negligible. It also means that we don’t have to be restricted to one “bay” for charging and it can stretch to the other side of the driveway.
How to use V2G/V2H Discharging:
- If the EV is at 80%, then you set the charge limit to +1% or greater, so that the EV is in a state that could be “ready to accept charge”
- EVDC handshakes CCS to “start charge” and then takes power out
We opted not to move our 4yo Ohme Home Charger 7.4kW from the old home even though it was solid and worked really well. It was looking cracked and tired the Scott the electrician thought it would spoil the aesthetic of a clean house with a Sigenstor. We left the Ohme behind to hopefully encourage the next tenant of that home to get an EV! So for AC charging, we depend on the 3-pin plug granny charger (2.3kW), or I may still ask Scott the electrician to come back to install a 32A Commando socket (think caravan hook-up) as I already have the 32A Commando adapter (7.4kW), but I am very aware I should really have a PEN device which we left behind with the Ohme.
EVDC Limitations & Considerations
Sigenergy 12.5kW EVDC Charger sits on the DC Bus, behind the inverter. This has benefits in that the EVDC can take power from Solar + Battery + Grid to reach 12.5kW, however if you are heavily dependent on off-peak imports at night, you are limited by the inverter size. In our case our total 6hrs of Octopus Intelligent Go import is 6hrs x 8.8kw = 52.8 kWh to share between the car & home battery. This might not be enough if you do a lot of mileage and have a big battery. You definitely need to be aware of this and make sure it isn’t limiting for your needs.
Charging at max rate of 12.5kW is possible by combining any of the following 3:
- Solar at up to 7.1kW
- Home Battery at up to 2x4.6 = 9kW
- Grid import via Solar Inverter at up to 8.8kW
Charging Off-Peak: The EVDC is currently hard coded to be higher priority than the home battery when it comes to charging and our 12.5kW EVDC charger will consume all 8.8kW and starve the home battery of any import. Therefore we generally limit the EVDC to 5.2kW to leave around 3kW for the 16kW home battery
Discharging V2G/V2H: From operating V2G/V2H and reading online, it seems that most EVs seem to only discharge at around 3 to 5kW (EV dependent) and may have a limit of 5kWh in a session before it throws a hissy fit. The Sigenergy EVDC simply taps into the DC pins and instead of providing juice, it extracts it (unofficial operation without protocols). So right now, it does not seem to be as dynamic as you would want with starting a session itself. I envisaged it behaving like a home battery with instant response but we are far from that. The EV does discharge to match the house load, but the home battery is always faster and more precise. Although this is car-dependent, having to unplug and re-plug when you reach that ~5kWh limit to reset V2G/V2H is annoying. I originally wanted to have only 1x 8kWh Home Battery (4.6kW max output) and depend on the car to provide the 3.4kW to the inverter - but I’m glad Scott talked me into have 2x 8kWh Home Batteries. With 1 battery, I would have ended up with far more grid import than I would have wanted.
Remember that the DC behaviour in a car is different to AC:
- Depending on the vehicle, when the target SoC is reached, the car simply sends a stop command and charging stops.
- Once charging has stopped, it doesn’t maintain a connection to allow taking power for e.g. preconditioning etc.
- So if you have a long journey in winter, you may wish to charge to ~95% in off-peak hours, and then charge that final ~5% from Solar + Home Battery in the 1 hour before you leave home, along with preconditioning.
Tips & Lessons Learnt
- Scaffolding forms a huge part of the cost of installation. Therefore for the scaffolding you have up, you need to maximise what you get out of it. Install the BEST panels you can, as panels generally cost ~£80 per panel, then paying ~£100 instead is not a lot of premium when you talk about 14 to 16 panels.
- Warranties… they seem to be an indication of how well the manufacturer thinks it will perform, but if you’re still liable to pay for the scaffolding to come up to change a single panel (covered under warranty), then I think a long warranty is not that important. So beware of anyone who is trying to sell you on long warranties and lifetime warranties as a USP
- For UK, make sure you choose a panel that is great for the grey weather
- EPS is probably not much cheaper if you have to have transfer switch, extra consumer units and rewiring. Gateway could be cost effective, more practical and much simpler
- Sigenergy EVDC Charger sits on the DC bus behind the inverter and therefore is limited by the solar inverter when it comes to importing from the grid. But that can be supplemented by Solar+Battery
- Your installer does not need to be MCS registered, but make sure there is NAPIT or similar accreditation and that your utility will accept it. Octopus Energy accept NAPIT for signing up to export. This might mean I’m stuck with Octopus forever, but I don’t mind that.
Bugs
- When the home battery is on 0.1% and the solar priority is 1)House 2)Grid 3)Battery, then the home battery suddenly ramps up to discharge at 4kW. This is a known bug and should be fixed in future. Workarounds are to have battery higher priority than Grid, or to set a 1% SoC limit rather than 0%.
Conclusion
The Sigenergy system has worked really well in the past 6 months and was definitely worth paying the premium for. The app is simply fantastic with so many ways to control what you want. The support has been good with responses within a few days and a thorough investigation / explanation.
The sizing of the battery was pretty much at fluke at 16kWh, we charge it up to 100% every night on off-peak 7p electricity. On most 5’C winter days it is sufficient to sustain the House & Heat Pump during the 18 hours of peak electricity hours. And when we are a bit short, we use the EV to provide a few kWh of its off-peak energy.
I can highly recommend the Sigenergy system and AIKO Solar PV panels. Thankfully we were in a position to buy the premium solution and I think its performance will give dividends over the next 30 years!
Products
Solar PV: 14x AIKO Neostar 2S+ 510W (7140W) Solar Inverter: Sigenergy 8kW Single Phase Home Battery: 2x Sigenergy 8.06 kWh (16.12 kWh) EV Charger: Sigenergy EVDC 12.5 kW with 10m cable Heat Pump: Vaillant aroTHERM 5kW with myVAILLANT Connect Under Floor Heating: ProWarm Lo-Flo